MFI #5, MFI #17 No Signal GRD
TD. MFI #5, MFI #17
MFI #5 No Signal GND
Fault Message Conditions:
The fault message is logged if voltage is above 1.2 V.
Causes of fault:
Break at the GND point on the intake manifold.
Fault symptoms:
If the break is intermittent the engine will stop or run rough.
MFI #17 No Power GND
Fault Message Conditions:
The fault message is logged if voltage is above 1.2 V. when engine speed is below 2500 rpm.
Causes of fault:
Break at the GND point on the intake manifold.
Fault symptoms:
The engine will not start.
If the break is intermittent the engine will stop or run rough.
TD1
Volvo ST, Test Box
-Disconnect the ST in accordance with QA2. Connecting The Volvo Scan Tool (ST)
-Connect the test box to MFI and check the GND points in accordance with P1-P2. Check the MFI#5 and MFI#17 very carefully.
-Continue with Checking the GND points TD2.
TD2
Checking The GND Points
If the reading Is OK when checking the GND points:
Intermittent fault.
-Check the GND point and connections to it for loose contacts.