Removal
2GR-FE BATTERY / CHARGING: GENERATOR: REMOVAL
1. PRECAUTION
NOTICE:
After turning the engine switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work Service Precautions.
2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Repair Instruction - Initialization.
3. REMOVE V-BANK COVER SUB-ASSEMBLY Removal
4. REMOVE RADIATOR ASSEMBLY
Removal.
5. REMOVE V-RIBBED BELT
Removal.
6. REMOVE GENERATOR ASSEMBLY
(a) Remove the terminal cap.
(b) Remove the nut and disconnect the wire harness from terminal B.
(c) Disconnect the generator connector from the generator assembly.
(d) Remove the bolt and disconnect the wire harness clamp.
(e) Remove the 2 bolts.
(f) Remove the 2 bolts and generator assembly.
(g) Disconnect the wire harness clamp and remove the generator bracket.