Measuring Connecting Rod Side Clearance
Measuring Connecting Rod Side Clearance
Using Dial Indicator
- Mount dial indicator to a stationary point on the engine. Locate the probe perpendicular to and resting against the connecting rod cap being checked.
- Move the connecting rod all the way to the rear of its travel.
- Zero the dial indicator.
- Move the connecting rod forward to the limit of travel and read the dial indicator. Compare the measured side clearance to the specification. Refer to => [ Piston, Pin and Ring Specifications ] [1][2]Piston, Engine.
- Repeat this procedure for each connecting rod. Rotate the crankshaft for connecting rod accessibility.
Using Feeler Gauge
- Slide a snug-fitting feeler gauge between the connecting rod and crankshaft journal flange. Compare the measured side clearance to the specification. Refer to => [ Piston, Pin and Ring Specifications ] [1][2]Piston, Engine.
- Repeat this procedure for each connecting rod. Rotate the crankshaft for connecting rod accessibility.