Generator Ribbed Belt Pulley
Generator Ribbed Belt Pulley
Special tools, testers and auxiliary items required
• Torque Wrench (V.A.G 1331/)
• Socket (VAS 3310)
Removing
- Remove generator --> [ Generator ] Generator.
- Tighten the generator in a vise at the attachment points.
- Use socket insert (VAS 3310) to remove mounting nut of overrunning clutch pulley from generator shaft.
Installing
Install in reverse order of removal, noting the following:
- Tighten the threaded connection between the ribbed belt pulley and generator shaft 65 Nm.