Canister Purge Control Valve: Testing and Inspection
Carbon canister shutoff valve, checking- connect hand vacuum pump US 1390 to small diameter connector 1
- with suction at connector 2
- valve must close
- operate vacuum pump
- valve MUST open
- test check valve 3. It must have flow in the direction of the arrow, and be closed in the opposite direction
If NO
- replace shutoff valve