P0A85
DTC P0A84 Hybrid Battery Pack Cooling Fan 1 Control Circuit LowDTC P0A85 Hybrid Battery Pack Cooling Fan 1 Control Circuit High
DESCRIPTION
DTC Detection Condition:
The blower motor controller regulates the voltage of the battery blower. The blower motor controller has fins made of aluminum. The exhaust air from the HV battery assembly that flows through the quarter vent duct cools the blower motor controller, which is installed in the quarter vent duct.
The current flows from the FCTL1 terminal of the battery ECU to the relay coil of the No. 1 battery blower relay and as the contact point of the relay closes, the power is supplied to the battery blower.
When a fan actuation signal is transmitted from the battery ECU, the blower motor controller adjusts voltage (VM) which is applied to the battery blower in order to get the requested fan speed. The adjusted voltage is also transmitted to the VM terminal of the battery ECU in the form of a monitoring signal. The blower motor controller corrects the voltage at the blower motor by monitoring voltage at the +B terminal of the battery blower.
Wiring Diagram:
Step 1:
Step 2-4:
Step 5:
Step 6-7:
Step 7(Continued)-9:
Step 9(Continued)-11:
Step 11(Continued)-13:
Step 14:
Step 15:
Step 16-17:
INSPECTION PROCEDURE