Air Conditioning System (For Automatic Air Conditioning System)
AIR CONDITIONING: AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System): TERMINALS OF ECU
TERMINALS OF ECU
1. CHECK AIR CONDITIONING AMPLIFIER
(a) Measure the voltage and resistance of the connectors.
HINT: Check from the rear of the connector while it is connected to the air conditioning amplifier.
HINT: *: for 2GR-FE
(b) Using an oscilloscope, check waveform 1.
HINT: *: Compressor and pulley for 2AZ-FE, Compressor and magnetic clutch for 2GR-FE.
(c) Using an oscilloscope, check waveform 2.
HINT: When the blower level is increased, the duty ratio changes accordingly.
(d) Using an oscilloscope, check waveform 3.
HINT: The waveform varies depending on the CAN communication signal.
(e) Using an oscilloscope, check waveform 4.
HINT: The waveform varies depending on the CAN communication signal.
(f) Using an oscilloscope, check waveform 5.
HINT: *: for 2GR-FE
2. CHECK AIR CONDITIONING CONTROL
(a) Measure the voltage and resistance of the connectors.