Test Point 5 - Evaporator Temperature Sensor

Test Point 5 - Evaporator temperature - Fault Code 8 _ 14

Temperature/Resistance
0° C (32° F) 8.8 - 9.2 Kohm
25°C (77° F) 2.6 - 2.9 Kohm

Possible Causes, Elimination, Remarks
- Measure resistance between G 18 and G 22.
- Check both electric sensor leads against ground.