2. Air Outlet Control Knob Moves, A/C Damper Motor Inoperative
When the air outlet changeover control knob is move to DEFROSTER or DEFROSTER/FOOT position, the air conditioning or the inside/outside air changeover damper motor does not operate.DIAGNOSIS
STEP 1. Check the inside/outside air damper controller continuity. <1999 models>
NOTE: Battery voltage should be supplied when the air outlet changeover knob is at the defroster or defroster/foot position.
If incorrect, replace. Then go to Step 4.
If correct, go to Step 2.
STEP 2. Check the defroster switch continuity.
<1999 models>
<2000 models>
If incorrect, replace. Then go to Step 4.
If correct, go to Step 3.
STEP 3. Check each A/C part.
Refer to Inspection Procedure 1. Then go to Step 4.
STEP 4. Check symptoms.
Check that the AC operates correctly.