Inspection Procedure 28
CIRCUIT OPERATION- The ECM
TROUBLESHOOTING HINTS
The most likely causes for this code to be set are:
- Malfunction of the fan motor relay.
- Malfunction of the fan motor.
- Malfunction of the fan controller.
- Improper connector contact, open circuit or short-circuited harness wire.
- ECM failed
- PCM failed .
WIRING DIAGRAM
CONNECTORS
DIAGNOSIS
STEP 1. Measure voltage at ECM connector C-35
1. Disconnect connector C-35
2. Turn the ignition switch "ON."
3. Measure voltage between terminal 21
- Voltage should be between 4.8 and 5.2 volts (the fan rotates at a high speed)
4. Connect a jumper cable between 21
- The fan should stop.
If the fan stops, go to Step 2.
If the fan does not stop, go to Step 3.
STEP 2. Check harness connector C-35 at the ECM
If harness connector C-35
If harness connector C-35
Then check that the malfunction is eliminated.
STEP 3. Check the harness wire between fan controller connector A-30 and ECM connector C-35
NOTE: Check The wire after checking intermediate connector C-04. If intermediate connector C-04 is damaged, repair or replace it. Refer to Harness Connector Inspection >. Then check that the malfunction is eliminated.
If the wire between fan controller connector A-30 and ECM connector C-35
If the wire between fan controller connector A-30 and ECM connector C-35
Then check that the malfunction is eliminated.