Air Cleaner Outlet Pipe Removal/Installation




AIR CLEANER OUTLET PIPE REMOVAL/INSTALLATION - 2.5L

1. Disconnect the crankcase vent tube from the Air Cleaner (ACL) outlet pipe.

2. If equipped, disconnect the vacuum tube from the ACL outlet pipe.

3. Disconnect the mass air flow (MAF) sensor electrical connector and the wiring harness retainer.

4. Loosen the 2 clamps and remove the ACL outlet pipe.

- To install, tighten to 4 Nm {0.4 kgf-m, 35 in-lbf}.

5. To install, reverse the removal procedure.

NOTE:The ACL outlet pipe should be securely sealed to prevent unmetered air from entering the engine.