A16 Check FLS No. 2
- Disconnect 2-pin plug from Fluid Level Switch (FLS) No. 2, located on hydraulic control unit reservoir.
- Measure resistance between pins 1 and 2 on hydraulic control unit reservoir.
- Is resistance less than five ohms?
YES -- Service or replace cable harness circuit 550 (Y/LG) or 535 (LB/R).
NO -- Replace hydraulic control unit reservoir.