P0206
DTC P0206
Injector circuit fault, cylinder 6 (Driving Cycle A)
Possible causes by suggested order of priority:
- Connectors C634, C157, C527.
- Circuit integrity C634/17 (YS) - C527/1 (YS).
- Circuit integrity C527/2 (NO) - C157/3 (NO).
- Supply from C157/3
- Injector
- ECM.
Connectors C634, C157, C527.
- Check for connector not correctly latched, backed out pins, damaged pins, corroded pins
Circuit integrity C634/17 (YS) - C527/1 (YS).
- Check for open circuit, short circuit to ground, supply or other circuit, damaged or unlatched connector, intermediate connectors or headers
Circuit integrity C527/2 (NO) - C157/3 (NO).
- Check for open circuit, short circuit to ground, supply or other circuit, damaged or unlatched connector, intermediate connectors or headers
Supply from C157/3
- Check voltage 10.0 to 14.0 volts
Injector
- Injector resistance.
PASS VALUES: 10 to 20 Ohms.
ECM.
- No detail available for this fault