Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 2 (Left Side) Exhaust
Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 2 (Left Side) Exhaust
Removal Procedure
1. Remove the air cleaner assembly. Refer to Air Cleaner Assembly Replacement (Service and Repair).
2. Remove the engine mount snubber bracket. Refer to Engine Mount Snubber Bracket Replacement (Engine Mount Snubber Bracket Replacement).
3. Disconnect the engine wiring harness electrical connector (4) from the bank 2 exhaust camshaft position (CMP) actuator solenoid valve.
4. Remove the CMP actuator solenoid valve bolt.
5. Remove the CMP actuator solenoid valve.
6. Inspect the CMP actuator solenoid valve seal for damage and replace as necessary.
Installation Procedure
1. Inspect the CMP actuator solenoid valve seal for damage. Replace the seal if necessary.
2. Install the CMP actuator solenoid valve.
Caution: Refer to Fastener Caution (Fastener Caution).
3. Install the CMP actuator solenoid valve bolt and tighten to 10 Nm (89 lb in).
4. Connect the engine wiring harness electrical connector (4) to the bank 2 exhaust CMP actuator solenoid valve.
5. Install the engine mount snubber bracket. Refer to Engine Mount Snubber Bracket Replacement (Engine Mount Snubber Bracket Replacement).
6. Install the air cleaner assembly. Refer to Air Cleaner Assembly Replacement (Service and Repair).