Starter Motor Noise Diagnosis
Starter Motor Noise Diagnosis
Diagnostic Aids
Inspect the flywheel ring gear for damage or unusual wear.
Test Description
The number below refers to the step number on the diagnostic table.
5. A starter motor that remains engaged after engine start up can be cause by a starter relay that hangs up or a low current short to B+ on the starter solenoid crank voltage circuit. Verify the integrity of the starter solenoid crank voltage circuit before replacing the starter motor.