Crankshaft: Testing and Inspection
Axial Clearance, Measuring
Special tools, testers and auxiliary items required
• Dial Gauge Holder (VW 387)
• Dial Gauge (VAS 6079)
Procedure
- Attach Dial Gauge (VAS 6079) together with Dial Gauge Holder (VW 387) to cylinder block and set indicator against crankshaft counterweight.
- Press crankshaft against dial indicator by hand, set indicator to - 0 -.
- Press crankshaft off dial indicator and read the value:
• Axial clearance: 0.15 to 0.25 mm.