Curiosii for ever!: Car repair manuals for everyone.

Crankshaft: Testing and Inspection






Axial Clearance, Measuring

Special tools, testers and auxiliary items required

Dial Gauge Holder (VW 387)

Dial Gauge (VAS 6079)

Procedure

- Attach Dial Gauge (VAS 6079) together with Dial Gauge Holder (VW 387) to cylinder block and set indicator against crankshaft counterweight.





- Press crankshaft against dial indicator by hand, set indicator to - 0 -.

- Press crankshaft off dial indicator and read the value:

Axial clearance: 0.15 to 0.25 mm.