Crankshaft: Testing and Inspection
Axial Clearance, Measuring
Special tools, testers and auxiliary items required
• Dial Gauge Holder (VW 387)
• Dial Gauge (VAS 6079)
Procedure
- Secure Dial Gauge (VAS 6079) with Dial Gauge Holder (VW 387) to cylinder block as shown in illustration.
- Position dial gauge against crankshaft counterweight.
- Press crankshaft by hand against gauge and set gauge to "0".
- Press crankshaft off gauge and read value.
• Axial clearance: 0.090 to 0.251 mm.