VSA Activation Indicator Does Not Come On at Start-Up (Bulb Check)
VSA activation indicator does not come on at start-up (bulb check)1. Turn the ignition switch ON (II), and watch the VSA activation indicator.
Does the VSA activation indicator come on for several seconds?
YES-The system is OK at this time.
NO-Go to step 2.
2. Do the gauge control module self-diagnosis function procedure.
Is the gauge control module OK?
YES-Go to step 3.
NO-Replace the gauge control module.
3. Turn the ignition switch OFF.
4. Substitute a known-good VSA modulator-control unit.
5. Turn the ignition switch ON (II).
Does the VSA activation indicator come on?
YES-Replace the VSA modulator-control unit.
NO-Check for loose terminals in the gauge control module connectors. If connections are good, replace the gauge control module.