Instrument Cluster - Loss of Memory
GROUP: 90NUMBER: 95-03
DATE: Apr. 11, 1995
SUBJECT:
Instrument Cluster, Loss of Memory
MODEL(s):
Passat m.y. 1995
File this Technical Bulletin In Repair Manual No.: W42 012 194 111
Supersedes T.B. 90-95-01 dated Feb 23, 1995
Condition
Loss of memory in the multi-function indicator (MFI) circuit for the clock and trip odometer due to insufficient voltage stabilization at temperatures of 32°F (0°C) and below.
Production
Revised voltage stabilizer installed in PC board of instrument cluster as of 1/23/95 with VIN:SE_134152
Service
- Remove instrument cluster Repair Manual Passat m.y. 1995 Electrical Equipment (W42012194111) Page 9O-1.
- Replace PC board on instrument cluster with:
PART NUMBER USAGE
3A0919042F Manual Trans. (USA)
3A0919042J Automatic Trans. (USA)
3A0919042D Manual Trans. (CAN)
3AO919042G Automatic Trans (CAN)
Caution
Part numbers are for reference only. Always check with your Parts Department for the latest parts information.
For warranty claims use:
Damage code:
9003 4O xxx2
Note:
xxx = Vendor code from part replaced.
Labor operation: 9003212
Diagnosis Repair Quality Check
- 5OTU 10TU
Note:
The above labor operation includes all steps necessary to complete repair.