Valve Block Right Front Inlet Solenoid Valve Resistance
1. Turn ignition off.2. Connect multimeter to terminal No. 11 and No. 15 of the ABS 35-pin connector.
3. Set multimeter to 200 Ohm scale. If reading is not 5-7 ohms, check the following:
a. Measure resistance between valve block contacts No. 1 and No. 2.
b. If reading is not as specified in step 3, find open circuit between valve block contact No. 2 and control unit contact No. 15.