Curiosii for ever!: Car repair manuals for everyone.

Inlet & Outlet Valve Block Solenoid Valves Ground Circuit

Fig. 2 ABS System Component & Connector Location (Part 1 Of 2).:





Fig. 2 ABS System Component & Connector Location (Part 2 Of 2).:





1. Turn ignition off.
2. Connect multimeter to terminal No. 1 and No. 11 of the ABS 35-pin connector.
3. Set multimeter to 2k Ohm scale. If meter does not read continuity, proceed as follows:
a. Disconnect hydraulic unit valve block 7-pin connector No. 27, Fig. 2.
b. Check for continuity between valve block housing and valve block contact No. 1.
c. If continuity exist in step B, check for continuity between valve block housing and ABS hydraulic unit.
d. If continuity exist in step C, jumper control unit harness contact No. 1 and No. 11.
e. Check for continuity between valve block connector contact No. 1 and No. 11.
f. Remove jumper wire.