Curiosii for ever!: Car repair manuals for everyone.

Maintenance-Free Batteries - Recharging

85VW1 Applies To All
Group


27
Subject Maintenance-free batteries


Part Identifier 2706
Key Points Recharging maintenance-free batteries in stock


(Supersedes Product Circular, Group 27, 84-01) C
Number

85-02


August 8, 1985
Check voltage of maintenance-free batteries in stock with a digital voltmeter, on a routine basis every eight (8) weeks.

If battery voltage is below 12.4 V (75% charged), recharge battery to full capacity.

After charging battery and before measuring voltage, remove surface charge by applying a 15 amp load for

15 seconds.

To prevent storage related problems, batteries in stock longest should be sold first.