Installation
2AR-FE EMISSION CONTROL: CANISTER: INSTALLATION
1. INSTALL CHARCOAL CANISTER LEAK DETECTION PUMP SUB-ASSEMBLY
(a) Engage the 2 claws to install a new charcoal canister leak detection pump sub-assembly to the canister.
NOTICE:
* Do not allow foreign matter such as grease, oil or water to adhere to the O-rings.
* Ensure that the claws are engaged properly.
2. INSTALL CHARCOAL CANISTER SUPPORT BRACKET
(a) Engage the claw to install the charcoal canister support bracket.
3. INSTALL CHARCOAL CANISTER BASE BRACKET
(a) Engage the claw to install the charcoal canister base bracket.
4. INSTALL CHARCOAL CANISTER ASSEMBLY
(a) Connect the clip to install the charcoal canister assembly.
(b) Install the 3 bolts and guide.
Torque : 8.0 Nm (82 kgf-cm, 71 in-lbf)
(c) Connect the air line tube.
NOTICE:
* Check that there are no scratches or foreign matter around the connected part of the tube connector and pipe before performing this work.
* After connecting the air line tube, check that the air line tube is securely connected by pulling on the tube connector and the charcoal canister.
(d) Connect the purge line hose.
(e) Connect the connector to the charcoal canister leak detection pump sub-assembly.
5. INSTALL FUEL TANK ASSEMBLY
Installation