Curiosii for ever!: Car repair manuals for everyone.

High Voltage Safety



High Voltage Safety



The HV battery pack powers the high voltage electrical system with direct current (DC) electricity. A positive and a negative power cable are routed from the battery pack, under the vehicle floor pan, to the inverter. Occupants in the vehicle and emergency responders are separated from high voltage electricity by the following systems:

High Voltage Safety System
- A high voltage fuse "1" provides short circuit protection in the HV battery pack.

- The positive and negative power cables "2" connected to the HV battery pack are controlled by 12-Volt normally open relays "3". When the vehicle is shut off, the relays stop electricity flow from the HV battery pack.

WARNING:
Power remains in the high voltage electrical system for 5 minutes after the HV battery pack is shut off.

Never touch, cut, or open any high voltage power cable or high voltage component.

- Both power cables "2" are isolated from the metal chassis, so there is no possibility of shock by touching the metal chassis.

- A ground fault monitor "4" continuously monitors for high voltage leakage to the metal chassis while the vehicle is running. If a malfunction is detected, the vehicle computer "5" will illuminate the master warning light in the instrument cluster and the hybrid warning light in the LCD display.

- The HV battery pack relays will automatically open to stop electricity flow in a collision sufficient to activate the front SRS airbags.