Service Hints
Power WindowP9 POWER WINDOW MASTER SW
1 - GROUND : Always approx. 12 volts
4 - GROUND : Approx. 12 volts with the ignition SW at ON position
9 - GROUND : Always continuity
B8 (A), B9 (B) BODY ECU
15 - GROUND : Approx. 12 volts with the ignition SW at ON position
(B) 9 - GROUND : Always approx. 12 volts