Ignition Coil: Testing and Inspection
INSPECT IGNITION COILS WITH IGNITERSa. Disconnect the high-tension cords from the ignition coils.
b. Inspect the secondary coil resistance.
Using an ohmmeter, measure the resistance between the
If the resistance is not specified, replace the ignition coil.
c. Reconnect the high-tension cords to the ignition coils.
d. Inspect the igniters. (See procedure spark test)