Service Hints
P7 POWER WINDOW MASTER SWBW-GROUND : Approx. 12 Volts with the ignition SW at on position
DU-GROUND : Approx. 12 Volts with the ignition SW on and master SW (Front LH window) at UP position
DD-GROUND : Approx. 12 Volts with the ignition SW ON and master SW (Front LH window) at DOWN or AUTO DOWN position
E-GROUND : Always continuity
WINDOW LOCK SW
Open with window look SW at LOCK position