Pick-Up Coil: Specifications
| NE to G- | Cold | 155 - 250 at 14 - 122 Ohms At Degrees Fahrenheit (ohms @ deg F) |
| Hot | 190 - 290 at 122 -212 Ohms At Degrees Fahrenheit (ohms @ deg F) | |
| G1 to G- | Cold | 125 - 200 at 14 - 122 Ohms At Degrees Fahrenheit (ohms @ deg F) |
| Hot | 160 - 235 at 122 - 212 Ohms At Degrees Fahrenheit (ohms @ deg F) | |
| G2 to G- | Cold | 125 - 200 at 14 - 122 Ohms At Degrees Fahrenheit (ohms @ deg F) |
| Hot | 160 - 235 at 122 - 212 Ohms At Degrees Fahrenheit (ohms @ deg F) |