Warm-Up Converter (Wu TWC)
Front Pipe Removal:
REMOVAL
1. Disconnect negative battery terminal.
2. Disconnect sub-oxygen sensor electrical connector.
3. Remove support bracket.
4. Using a 14mm deep socket, remove two nuts securing the front pipe to the warm-up converter.
5. Remove remaining front pipe bolts and remove pipe.
Converter Brace:
6. Remove bolts and converter brace.
Converter Removal:
7. Remove converter and gasket.
Heatshield Attachment:
8. Remove securing nuts and remove heat shield.
Gasket Installation:
INSTALLATION
1. Install converter using a new gasket and new nuts.
Torque to: 22 ft.lb (29 Nm)
Manifold Support:
2. Install manifold support.
Torque to: 29 ft.lb (39 Nm)
3. Reverse remainder of procedure to complete.