Ignition Cable: Testing and Inspection
- Disconnect the high-tension cords at rubber boot. Do not pull on the cords.NOTICE: Pulling on or bending the cords may damage the conductor inside.
- Remove distributor cap.
- Measure resistance between spark plug connector and distributor terminal.
Maximum resistance: 25 k ohms
- If resistance is high, check distributor terminals.
- If necessary replace cap and/or wire.