Installation
2GR-FE STARTING: STARTER: INSTALLATION
INSTALLATION
1. INSTALL STARTER ASSEMBLY
(a) Install the starter assembly with the 2 bolts.
Torque: 37 Nm (377 kgf-cm, 27 ft-lbf)
(b) Connect the starter connector.
(c) Connect the starter wire with the nut and cover the nut with the cap.
Torque: 9.8 Nm (100 kgf-cm, 87 in-lbf)
2. INSTALL AIR CLEANER BRACKET
(a) Install the bracket with the 2 bolts.
Torque: 12 Nm (120 kgf-cm, 9 ft-lbf)
3. INSTALL AIR CLEANER CASE SUB-ASSEMBLY
4. INSTALL AIR CLEANER CAP SUB-ASSEMBLY
5. INSTALL NO. 1 AIR CLEANER INLET
6. INSTALL NO. 2 AIR CLEANER INLET
7. INSTALL BATTERY
8. INSTALL COOL AIR INTAKE DUCT SEAL