Removal and Installation
COMPONENTS
REMOVAL
1. DISCONNECT WIRING FROM GENERATOR
a. Disconnect the connector from the generator.
b. Remove the nut and disconnect the wire from the generator.
2. REMOVE GENERATOR DRIVE BELT
a. Loosen the adjust lock nut, adjusting bolt and pivot bolt.
b. Remove the drive belt.
3. REMOVE GENERATOR
a. Remove the pivot bolt and adjusting lock nut
b. Remove the generator.
Torque:
Pivot bolt: 51.0 N.m (520 kgf.cm, 38 ft.lbf)
Lock Nut: 18.5 N.m (185 kgf.cm, 14 ft.lbf)
INSTALLATION
Installation is in the reverse order of removal