Charging Circuit With Load
CHARGING CIRCUIT WITH LOAD1. With the engine running at 2,000 rpm, turn on the high beam headlights and place the heater blower switch at "HI".
2. Check the reading on the ammeter.
Standard amperage:
30 A or more
If the ammeter reading is less than the standard amperage, repair the generator.
HINT: If the battery is fully charged, the indication will sometimes be less than the standard amperage.