Ignition Coil: Testing and Inspection
Measuring Ignition Coil Resistance:
- Pull out high tension cord by gripping its cap.
- Disconnect ignition coil connector.
- Measure primary and secondary coil resistances.
PRIMARY RESISTANCE
0.72 - 0.88 ohms (at 20° C, 68° F)
SECONDARY RESISTANCE
10.2 - 14.0 Kohms (at 20° C, 68° F)
- Replace coil if results differ.