Pick-Up Coil: Testing and Inspection
Measuring Pick-Up Coil Resistance:
- Disconnect distributor electrical connector.
- Using an ohm meter, measure the resistance of the pick-up coil.
RESISTANCE VALUE
588 - 888 ohms @ 20° C (68° F)
- Replace if out of specification.