Positive Crankcase Ventilation Valve: Service and Repair
PCV Valve Removal and InstallationRemoval
1. Disconnect PCV hose from PCV valve.
2. Remove PCV valve from cylinder head cover.
Installation
Reference: PCV Valve Inspection
1. Apply sealant to thread part of PCV valve (1).
"A": Water tight sealant 99000-31250 (SUZUKI Bond No. 1207F)
2. Install PCV valve (1) onto cylinder head cover.
Tightening torque
PCV valve (a): 27 N.m (2.7 kg.m, 19.5 lbf.ft)
3. Connect PCV hose (2) to PCV valve (1).