Resonator: Service and Repair
AIR CLEANER OUTLET RESONATOR REPLACEMENT
REMOVAL PROCEDURE
1. Disconnect the intake air temperature (IAT) sensor connector
2. Loosen the clamp at the air cleaner assembly.
3. Remove the push pin attachment from the outlet resonator/duct assembly to support bracket.
4. Loosen the clamp at throttle body assembly.
5. Disconnect the PCV fresh air vent hose at cam cover.
6. Remove the outlet resonator/duct assembly.
INSTALLATION PROCEDURE
1. Install the outlet resonator/duct assembly into position at the throttle body and air cleaner.
2. Connect the PCV fresh air vent hose assembly.
3. Tighten the clamp at the throttle body assembly.
4. Position the outlet resonator/duct assembly up with the support bracket and install the push-pin.
5. Tighten the clamp at the air cleaner assembly.
6. Connect the intake air temperature (IAT) sensor connector.