Engine Management System, Trionic OBD II
Changed Diagnostic Trouble Codes
ISAT Scan Tool
^ Activation of the shut-off valve for the evaporative emission canister does not work on M96 1/2. Rectified from M97.
^ Tank pressure shows incorrect value for negative pressure. Rectified in the Tech 2.