Air Diverter Valve: Testing and Inspection
Chart C-6 A.I.R. Diverter Valve Control:
Wiring Diagram for Chart C-6 A.I.R. Diverter Valve Control:
CHART C-6 ELECTRIC DIVERT CONTROL
Circuit Description:
This system uses a single bed converter and air management is controlled by an air control valve (divert valve). When grounded by the ECM, the solenoid causes the valve to direct air to the exhaust ports. When deenergized air diverts to the atmosphere. Air will go to the ports provided the valve has a ground to the ECM and good manifold vacuum.
Test Description: Numbers below refer to circled numbers on the diagnostic chart.
1. This is a system performance test. When vehicle goes to "Closed Loop", air will switch from the ports to divert.
2. Tests for a grounded electric divert circuit. Normal system light will be "OFF".
3. Checks for an open control circuit. Grounding test terminal will energize the solenoid if ECM and circuits are normal. In this step, if test light is "ON", circuits are normal and fault is in valve connections or valve.