Charge Indicator Lamp Operation
The powertrain control module (PCM) controls the charge indicator lamp in the instrument cluster. The PCM sends a message to the instrument cluster through the Class II serial data link to turn on the charge indicator lamp when detecting one of these conditions:- Undervoltage (less than 11.2V).
- Overvoltage (over 16.5V).
- Stopped generator.