Test E - Isolation Test
Isolation Test:
1. Remove the connector from the A/C Compressor Control Relay and measure the voltage to ground at the following terminals of the connector.
^ if voltages are correct, proceed to step 2.
^ If voltage is correct at only one terminal, check for an open in LT GRN (66) wire.