Compressor Motor Test
Connect a fused jumper between terminal A ORN (40) wire and the DK GRN (322) wire of the ELC compressor assembly. Put the ignition switch in OFF position.
1. If the compressor runs, continue and test the vent solenoid.
2. If the compressor does not run, check the BLK wire for an open. Check that G405 is clean and tight.
3. If no wiring problem is found, remove the ELC compressor assembly for repair.