A/C Auto Amp
A/C AUTO AMP.
Fail-Safe
FAIL-SAFE FUNCTION
- If a communication error exists between the A/C auto amp., the AV control unit and A/C and AV switch assembly for 30 seconds or longer, air conditioner is controlled under the following conditions:
Compressor: ON
Air outlet: AUTO
Air inlet: FRE (Fresh)
Blower fan speed: AUTO
Set temperature: Setting before communication error occurs
Display: OFF