High Pressure Cut Switch
1. Start engine and turn A/C on, then measure continuity of switch while measuring pressure in high pressure line.
2. Ensure that switch turns compressor off when pressure increases to 356-412 psi.
3. Ensure that switch turns compressor on when pressure decreases to 270-327 psi.