A/T Fluid Temperature Sensor Check
A/T FLUID TEMPERATURE SENSOR CONTINUITY CHECK1. Remove the A/T fluid temperature sensor.
2. Measure the resistance between terminals 1 and 2 of the A/T fluid temperature sensor connector.
Standard value
3. If the A/T fluid temperature sensor resistance is outside the specified range and the "N" range indicator light is flashing, replace the A/T fluid temperature sensor.
NOTE: The "N" range indicator light on the combination meter flashes when the temperature reaches approximately 125°C (257°F) or greater, and then stops flashing when the temperature drops below approximately 115°C (238°F).