| Generator drive belt vibration frequency | When checked | | 143 - 185 Hz |
| When a used belt is installed | | 155 - 175 Hz |
| When a new belt is installed | | 203 - 234 Hz |
| Generator drive belt tension | When checked | | 294 - 490 N |
| When a used belt is installed | Standard | 343 - 441 N |
| When a new belt is installed | Standard | 588 - 784 N |
| Generator drive belt deflection (Reference value) | When checked | Standard | 9.7 - 12.9 mm |
| When a used belt is installed | Standard | 10.5 - 12.0 mm |
| When a new belt is installed | Standard | 6.7 - 8.5 mm |
| Power steering oil pump and A/C compressor drive blet vibration frequency | When checked | Standard | 114 - 139 Hz |
| When a used belt is installed | Standard | 121 - 133 Hz |
| When a new belt is installed | Standard | 145 - 166 Hz |
| Power steering oil pump and A/C compressor drive belt tension | When checked | Standard | 392 - 388 N |
| When a used belt is installed | Standard | 441 - 539 N |
| When a new belt is installed | Standard | 637 - 833 N |
| Power steering oil pump and A/C compressor drive belt deflection (Reference value) | When checked | Standard | 10.0 - 12.0 mm |
| When a used belt is installed | Standard | 10.0 - 11.0 mm |
| When a new belt is installed | Standard | 7.2 - 9.0 mm |
| Basic ignition timing at idle | | Standard | 5 deg BTDC +/- 3 deg |
| Actual ignition timing at curb idle | | Standard | Approximately 5 deg BTDC |
| CO contents | | Standard | 0.5% or less |
| HC contents | | Standard | 100 ppm or less |
| Curb idle speed | | Standard | 700 +/- 100 r/min |
| Intake manifold vacuum at curb idle | | Limit | Minimum 60 kPa |
| Cylinder head bolt shank length | | Limit | 96.4 mm |