Brake Proportioning/Combination Valve
Testing Specifications| Decompression Ratio | 0.25 | ||
| Split Point | 2-Door Models | Standard Value | 2.45 +/- 0.25 MPa |
| 4-Door Models | Standard Value | 2.94 +/- 0.25 MPa | |
| Output Fluid Pressure [Input Fluid Pressure] | 2-Door Models | Standard Value | 4.30 +/- 0.39 MPa |
| 4-Door Models | Standard Value | 4.66 +/- 0.39 MPa | |
| Left/Right Proportioning Valve Output Pressure Difference | Limit | 0.39 MPa |