Vacuum Tank Check
VACUUM TANK CHECK
1. Connect a hand vacuum pump to vacuum tank A nipple, apply 67 kPa of vacuum and check that the vacuum is held.
2. Connect a hand vacuum pump to vacuum tank B nipple.
3. First, close A nipple with your finger and apply 67 kPa of vacuum. Then, check that vacuum leaks immediately when you remove the finger blocking the nipple.