Curiosii for ever!: Car repair manuals for everyone.

Heated Oxygen Sensor Monitor


HEATED OXYGEN SENSOR MONITOR TEST (DTC P0130, P0136)





REQUIREMENTS/PROCEDURE
1. Test requirements/procedure
(1) Engine coolant temperature: 80°C (176°F) or more (Engine fully warmed up)
(2) Atmospheric temperature: 10°C (14°F) or more
(3) Condition of A/T:
- Selector lever position: D range
- Overdrive switch: ON
2. One trip monitor will be completed by driving according to the steps below (from start to switch off). It will take 5 minutes.
*1: After warming up the engine, turn off the ignition switch.
*2: Start the engine, and accelerate to 56 - 64 km/h (35 - 40 mph).
*3: Drive between 56 and 64 km/h (35 and 40 mph) at a constant throttle angle (by not moving the throttle pedal as much as possible) for 120 seconds or more during monitor. Moreover, do not turn the steering wheel suddenly.
*4: Decelerate and stop the vehicle. Then turn off the ignition switch.