Battery
Type 75D26R-MFAmpere hours (5HR) 52 Ah
Cranking ratings [at - 18°C (0°F)] 490 A
Reserve capacity 123 min
NOTE:
1. CRANKING RATING is the current a battery can deliver to 30 Seconds and maintain a terminal voltage of 7.2 Volts or greater at a specified temperature.
2. RESERVE CAPACITY RATING is the amount of time a battery can deliver 25 A and maintain a minimum terminal voltage of 10.5 at 27°C (80°F).